A338-26 · Aneroid
c.1890
Object Overview
Here we have a Two-Stage Chain Transmission Aneroid Barometer: an unusual wall-mounted aneroid barometer, made around 1890 and sold in Nuremberg, Germany, by the optician Carl Leidig, Royal Bavarian Purveyor to the Court (Königlich Bayerischer Hoflieferant).
The barometer is of particular interest for its rare and technically curious movement. It has a two-stage chain transmission, an intermediate arbor, and two drums of different diameters on one axis. This design is an unusual variant of the traditional Vidie aneroid movement. Its extra complexity comes from the aim of obtaining a large angular deflection of the pointer from a relatively small displacement of the sensing element. The additional kinematic links inevitably introduced new sources of friction and mechanical error, which was probably one of the reasons why such movements are extremely rare.
aneroid capsule tensioned on a C-spring
brass, cardboard, carved wood, cast iron, glass, nickel silver, steel
The barometer case is round, turned and made for wall mounting. Its expressive multi-stepped profile combines smooth curved surfaces with geometrically crisp decorative elements. It is made of beech stained to a warm walnut tone and complemented by ebonised parts, stained black. The contrast between the polished wood, the dark decorative elements and the brass frame of the dial gives the instrument an elegant yet restrained appearance.
The front of the case is formed by a wide convex wooden rim with smoothly rounded edges. Its inner circumference is decorated with a massive ebonised carved ring bearing a leaf frieze of rhythmically repeated stylised pointed leaves. Each leaf has a pronounced central ridge and sloping facets, so that lit and shaded planes alternate around the whole circumference.
Behind the carved ring, the front rim turns into a deep, smooth cove. An ebonised half-round moulding (an astragal) separates the cove from the side wall of the case. The smooth transition between convex and concave surfaces gives the case additional depth and visually divides it into several concentric levels.
The side wall is a wide cylindrical band of stained beech with a smooth polished surface. Its warm brown colour and the clearly visible grain of the flat-sawn wood contrast with the black moulded details of the front. At the back, the side wall ends in a second ebonised moulding and a narrow black edge, which form a neat transition to the back of the case.
The back is flat, turned from stained beech, with a matt, unpolished surface. At its centre is a black-painted zinc protective cover, fixed with screws, which closes the inner cavity holding the measuring movement. The cover bears the engraved monogram D&R at its centre, probably that of a wholesaler. The wood above the cover carries a shallow marking "405", which is either the wholesaler's catalogue number or a factory or assembly number.
At the top of the case is a massive round brass suspension ring. It is attached to a turned spherical brass boss mounted on a threaded stem screwed directly into the wooden case. This arrangement ensures that the instrument hangs securely and vertically on the wall.
A small retailer's plate is fixed to the lower part of the front rim. It is a light-coloured metal plate with a black frame, shaped edges and cut corners, attached with two rivets. It bears a three-line inscription:
Optiker Leidig
Kgl. bayer. Hoflieferant
Nürnberg
The inscription refers to the optical business of Carl Leidig in Nuremberg and to his status as Royal Bavarian Purveyor to the Court. The presence of such a plate shows that the instrument was sold through a specialist optician's shop.
A classic wholesale arrangement was therefore probably at work. A large manufacturer, possibly Wilh. Lambrecht, made the movement and a cabinetmaker made the case. A wholesaler then assembled the instrument, added his mark (D&R) and his catalogue number, and sold it to court opticians in Nuremberg, Munich and Strasbourg. Opticians in at least these three cities are known to have sold barometers bearing the additional D&R mark. The optician put his own name on the dial or on a separate plate. Thousands of domestic barometers passed through such wholesale firms.
The dial is of the open type, made of card on a zinc backing. It is protected by a massive flat mineral glass with a wide bevelled edge, set in a brass bezel.
The dial carries an unusual barometric scale, arranged concentrically around the central opening. Unlike most traditional aneroid barometers, the scale of this instrument runs right around the dial and is designed to be used over its whole marked range.
The extreme values here are not a nominal decorative extension of the familiar barometric scale that the pointer almost never reaches. On the contrary, the graduation is a fully functional measuring scale. It is designed for the reduced range of atmospheric pressure typical of places at some height above sea level, such as Nuremberg, the seller's own city.
The scale is graduated in centimetres of mercury and covers the range from 70 to 76 cmHg. The value 76 cm, which corresponds to 760 mmHg and standard atmospheric pressure, is not at the top of the dial as on most ordinary aneroids. Instead it sits almost at the very bottom and corresponds to the weather term "Very dry" rather than the traditional "Change". The start of the scale, 70 cmHg, is also at the bottom of the dial, to the left of the central axis, and corresponds to "Storm". Thanks to this arrangement, the numbered graduation runs a full circle.
The weather indications corresponding to each centimetre of mercury are as follows:
All the weather terms are executed in a single decorative style, in large capital letters with characteristic horizontal hatching inside the characters and a dark three-dimensional shadow. The inscriptions follow the curve of the scale around the dial and form an expressive composition that combines the practical measuring function with decorative typography.
The extremely fine graduation of the measuring scale is particularly striking. Each centimetre of mercury is divided into twenty equal parts of 0.05 cm, or 0.5 mmHg. Thus one main interval between adjacent whole values contains twenty small divisions. This graduation corresponds to approximately 0.667 hPa per division and allows very detailed visual reading of changes in atmospheric pressure.
With such a wide angular sweep of the pointer, even relatively small changes in atmospheric pressure produce a clearly visible movement. As a result, the direction of the change can be followed directly on the main pointer while the pressure is changing, without constantly relying on the additional set hand to record the tendency. This does not make the set hand entirely useless, but it makes visual observation of current pressure changes considerably easier.
Such a detailed scale, occupying almost the entire circumference of the dial, called for an unusual technical solution. To give the barometric pointer an angular travel close to a full revolution from very small displacements of the aneroid capsule, the maker used a special multiplying mechanism that is rarely found in aneroid barometers.
The instrument is driven by a technically interesting movement with a two-stage chain transmission and an intermediate rotating arbor. In the traditional Vidie aneroid design, the motion of the main lever system is transmitted directly to the pointer arbor by a single fusee chain. Here, an additional stage of mechanical multiplication is used instead, formed by two coaxial drums of different diameters. This made it possible to increase the angular deflection of the barometric pointer without substantially enlarging the main lever mechanism.
The main sensing element is a round corrugated aneroid capsule 75 mm in diameter, made of nickel silver, a copper-nickel-zinc alloy widely used in instrument making. The capsule is hermetically sealed and its inner cavity is evacuated, so changes in external atmospheric pressure cause elastic deformation of its diaphragms. The rigid centre of the lower diaphragm is fixed to a massive cast-iron mounting plate with a decorative protective finish, which forms the base of the whole movement.
The capsule is pre-tensioned by a C-shaped steel spring with a protective finish. The lower end of the spring is fixed in a brass crossbar, a two-armed lever resting on two pointed supports. This design allows small angular movements of the crossbar with minimal friction at the support points. The elastic force of the spring counteracts the deformation of the aneroid capsule and takes part in establishing the mechanical equilibrium of the measuring system.
A long brass main lever runs from the upper free end of the C-spring and transmits the displacement of the sensing element to the next part of the movement. Through an oblique connecting link, it is joined to a bell crank mounted on a horizontal rotating shaft with centre bearings. When atmospheric pressure changes, the deformation of the capsule moves the C-spring and the main lever. The oblique link converts this movement into a small angular motion of the shaft. The first, relatively short fusee chain runs from the vertical arm of the bell crank and transmits the motion to the intermediate arbor.
The intermediate arbor is vertical, parallel to the pointer arbor, and is mounted between two brass support plates joined by cylindrical pillars. The upper plate has a characteristic lozenge shape that closely repeats the design of the pointer arbor's support. The ends of the intermediate arbor are made as fine pointed pivots turning in matching centre bearings.
A composite brass drum with two different working diameters is rigidly fixed to the intermediate arbor. Its upper part is a relatively narrow cylindrical hub of small diameter, onto which the first, input fusee chain coming from the bell crank of the main shaft is wound. The lower part is a wide flat disc of considerably larger diameter, and the second, output fusee chain runs around its cylindrical rim. Both parts of the drum form a single rigid whole and turn at the same angular velocity.
Thus the first chain, acting on the small-diameter hub, turns the intermediate arbor. At the same time, the large drum fixed to the same arbor takes up or pays out the second chain. Since the working radius of the large drum is considerably greater than that of the small one, the output chain travels a much greater distance than the input chain for the same angle of rotation. The intermediate arbor therefore does not merely change the direction of the transmission: it acts as a mechanical multiplier of linear displacement.
The second, much longer fusee chain runs from the rim of the large drum to the pointer arbor, which is located above the central part of the aneroid capsule. It winds onto a small drum on the pointer arbor and converts the translational motion of the chain into rotation of the barometric pointer. Like the intermediate arbor, the pointer arbor is held by two lozenge-shaped brass support plates mounted on cylindrical pillars.
The pointer arbor carries the only flat spiral hairspring in the movement. It provides a constant restoring torque that pre-tensions the whole serial chain transmission, takes up free play in the joints, and returns the pointer when the sensing element reverses direction. Thanks to this spring, both fusee chains are kept constantly under tension and the parts of the movement maintain the necessary force contact. A single hairspring thus serves not only the pointer arbor but the entire two-stage transmission.
As a result, the kinematic chain of the instrument runs in the following sequence: aneroid capsule — C-spring — main lever — oblique link — bell crank of the main shaft — first fusee chain — small hub of the intermediate drum — large drum of the intermediate arbor — second fusee chain — pointer arbor with hairspring — barometric pointer.
The main reason for using such an unusual movement was most likely the maker's wish to obtain a larger angular deflection of the pointer from a relatively small displacement of the aneroid capsule. The aim was to do this without excessively lengthening the arms of the main lever mechanism or reducing the diameter of the pointer arbor's drum.
This solution appears particularly well founded given the design of this barometer's dial. The barometric scale occupies the entire circumference of the dial and is exceptionally finely graduated. To give adequate spacing between the neighbouring divisions of such a detailed scale, a large angular travel of the pointer had to be obtained from a very small deformation of the sensing capsule.
In an ordinary aneroid movement, the displacement is magnified mainly by choosing the arm lengths of the transmitting levers and by reducing the working radius of the pointer arbor's drum. Both methods, however, have practical limits. Longer levers need more space, demand greater stiffness and may increase the influence of elastic deformation. Excessively reducing the diameter of the pointer drum makes it harder for the fine chain to wind evenly, increases the relative influence of geometric errors in its links and limits the torque that can be transmitted.
The intermediate arbor with two drums of different diameters made it possible to split the magnification into two successive stages. The first converts the motion of the bell crank into rotation of the intermediate arbor. The second increases the linear travel of the output chain through the difference between the working radii of the drums. The magnified displacement is then transmitted to the drum of the pointer arbor.
The physical principle of such a multiplier is quite simple. Let the working radius of the small input drum of the intermediate arbor be r₁, the radius of the large output drum r₂, and the radius of the pointer arbor's drum r₃. If the first chain moves by a distance s₁, the intermediate arbor turns through the angle:
φ₁ = s₁ / r₁.
Since both drums are rigidly fixed to the same arbor, their angular displacement is the same. The linear displacement of the second chain is then:
s₂ = φ₁ × r₂ = s₁ × r₂ / r₁.
Consequently, the linear magnification factor of the intermediate arbor is determined solely by the ratio of the working radii of its drums:
K = r₂ / r₁.
If, for example, the radius of the large drum is three times that of the small one, the output chain will move three times as far as the input chain as the intermediate arbor turns.
The second chain turns the drum of the pointer arbor, so the final angular displacement of the pointer is given by:
φₚ = s₁ × r₂ / (r₁ × r₃).
Compared with connecting the first chain directly to a pointer drum of the same radius r₃, the additional stage therefore increases the angular displacement of the pointer by a factor of r₂ / r₁. This magnification is achieved without having to reduce the working radius of the pointer drum in the same proportion.
Despite its obvious kinematic advantages, the two-stage chain transmission has a number of significant drawbacks, which probably limited its use.
First of all, increasing the angular displacement of the pointer inevitably reduces the torque available at its arbor for a given input force. A mechanical multiplier creates no additional energy; it only changes the ratio between displacement and force. A more sensitive indication therefore requires sufficient force from the aneroid capsule and the main spring, as well as particularly low resistance in all the transmitting elements.
The additional rotating arbor increases the number of friction points. Even with carefully finished pointed pivots, the resistance in the bearings of the intermediate arbor inevitably adds to that of the pointer arbor. In addition, two successive fusee chains have their own flexibility, elasticity and certain geometric errors arising from the shape and relative position of their links. Dirt, corrosion or impaired free flexing of even one chain can delay the movement of the pointer and increase the mechanical hysteresis of the instrument.
A further complication is the need to match the whole transmission to a single hairspring. Its restoring torque must be sufficient to keep both chains under constant tension and to overcome the resistance of two rotating arbors. At the same time it must not be so great that it overloads the aneroid capsule and distorts its sensitivity to changes in atmospheric pressure. As the transmission ratio increases, so does the load from the pointer spring as referred back to the input of the mechanism. The choice of drum diameters, spring characteristics and main lever geometry therefore required careful calculation and adjustment.
Finally, such a design placed high demands on the precision of the parts. Correct operation required well-aligned, freely rotating arbors, precisely machined cylindrical drum surfaces, even motion of both chains and no lateral drift. Every additional part increased the labour of assembly, adjustment and subsequent maintenance.
It is this combination of circumstances that probably explains the extreme rarity of such movements. The traditional single-stage Vidie transmission was much simpler, cheaper to make and easier to adjust, and it fully met the requirements of most domestic and scientific aneroid barometers.
This aneroid barometer is an interesting example of how the traditional decorative styling of late nineteenth-century wall-mounted meteorological instruments could be combined with an unusual and technically complex measuring movement. Its carefully worked wooden case, contrasting ebonised carving, expressive dial typography and large central window revealing the aneroid capsule at work all show the maker's wish to unite the function of a measuring instrument with the aesthetic appeal of a technical device.
With its unusual measuring scale, technically original two-stage movement, open display of its mechanism and characteristic period styling, this example holds a special place among the aneroid barometers of its time. It is a rare witness to the engineering experiments that accompanied the development of mechanical barometry in the nineteenth century.